MEMS-based flow meter using an Ionic Polymer-Metal Composite Sensor

Design Concept

  • The proposed MEMS-based vortex flowmeter can be used in small- scale applications that necessitates devices with low power requirements.
  • Ideally, the goal is to construct a small flow meter device (10 mm diameter) with the principle sensor being comprised of the electroactive polymer, an ionic polymer metal composite. IPMCs demonstrate sensing capabilities with heightened sensitivity.
  • A successful attempt at this scale could demonstrate the feasibility of using this type of flow sensor in even smaller scale devices.

Mechanism of Typical Vortex Flow Meter

A standard vortex flow meter operates based on the fluid phenomenon known as Karman Vortex Streets. When flow is disrupted by an obstruction object or bluff body, vortices are shed from the object which is correlated to the following relationship known as the Strouhal number:

Equation

where, 𝑓 is the frequency of vortex shedding, L is the characteristic length or hydraulic diameter of the object, and U is the flow velocity.

This relationship can then be related to Reynolds number where under a large Reynolds number range, Strouhal number is approximately 0.20.

A sensor can thus detect the frequency of the shed vortices, which is directly proportional to the flow velocity.

MEMS
MEMS

From Shanghai Yinuo Instrument Co. (Left) Cross section illustration of flow disruption in a pipe, generating vortices. (Right) Typical large vortex flow meter device.

MEMS

Strouhal Number as a function of Reynolds Number. Image from Thermopedia

Advantages and Disadvantages

Advantages

  • Silent in use
  • No moving parts
    • Less degradation
  • Flexible usage range
    • 100 < Re < 200,000
  • Low Power Requirements
  • IPMC sensitivity can sense mild displacements that will occur from shed vortices

Disadvantages

  • Requires analysis within the frequency domain to acquire velocity
  • Flow must be continuous for measurement (no pulsating flow)

Concept and Prototype Design

Initial Version

MEMS
MEMS

Subsequent and Final Version

MEMS

Failed and Completed Prints

MEMS

Physics Model - Visualization and Anticipation of Vortex Shedding

  • A physics-based model was developed in COMSOL Multiphysics.
  • Laminar flow physics was applied to a geometry resembling the cross-sectional area of the flowmeter device.

MEMS

Water at room temperature was set as the material and the normal inflow velocity was set to 0.07 m/s after an initialization step which was implemented to help the model run

Equation

Equation

Equation

Using the Reynolds number equation, this puts us at a Reynolds number of about 235.

MEMS

Experimental Setup

MEMS

  • A contact piece was designed and soldered to read the IPMC signal.
  • A Masterflex L/S series peristaltic pump was used to control the flow rate of the flowmeter.
    • The flow rate was calibrated to the specific hosing used.

Equation

Equation

  • Which results in a Reynolds number of 252, and thus an expected vortex shedding frequency of 4.76

MEMS

Results

MEMS

  • We can see the IPMC sensing the flow of the peristaltic pump in the following voltage reading plot.
  • An FFT was performed on 2 of the 3 runs.
  • Interestingly enough, we observe a noticeable frequency peak at around 4.7-5.0 Hz.
  • However, it is important to note, this coincidentally is also the peristaltic pump pulse frequency as well.

MEMS

Conclusion/Future Work

  • More experiments will have to be performed to validate the concept of the this design.
  • Possible improvements:
    • A pulse dampener can be implemented into the setup
    • Redesigning the flowmeter
      • Better access to main chamber
      • Less clunky contact design
      • Further miniaturization
Nazanin Minaian
Nazanin Minaian
Ph.D. Candidate | Graduate Research Assistant

My research interests include electroactive polymers, flow sensing, energy harvesting, and computer vision.